Recent interest in pile-up mitigation through fast timing at the HL-LHC has focused attention on technologies that now achieve minimum ionising particle (MIP) time resolution of 30 picoseconds or less. The constraints of technical maturity and radiation tolerance narrowed the options in this rapidly developing field for the ATLAS and CMS upgrades to low gain avalanche detectors and silicon photomultipliers. In a variety of applications where occupancies and doses are lower, devices with pixel elements of order 1 cm2, nevertheless achieving 30 ps, would be attractive. In this paper, deep diffused Avalanche Photo Diodes (APDs) are examined as candidate timing detectors for HL-LHC applications. Devices with an active area of 8 × 8 mm are characterised using a pulsed infrared laser and, in some cases, high energy particle beams. The timing performance as well as the uniformity of response are examined. The effects of radiation damage on current, signal amplitude, noise, and timing of the APDs are evaluated using detectors with an active area of 2 × 2 mm. These detectors were irradiated with neutrons up to a 1-MeV neutrons fluence cm−2. Their timing performance was characterised using a pulsed infrared laser. While a time resolution of ps was obtained in a beam test using an 8 × 8 mm sensor, the present study only demonstrates that gain loss can be compensated by increased detector bias up to fluences of cm−2. So it possibly falls short of the cm−2 requirement for the CMS barrel over the lifetime of the HL-LHC.

Deep diffused APDs for charged particle timing applications: Performance after neutron irradiation

M. Centis Vignali;
2020-01-01

Abstract

Recent interest in pile-up mitigation through fast timing at the HL-LHC has focused attention on technologies that now achieve minimum ionising particle (MIP) time resolution of 30 picoseconds or less. The constraints of technical maturity and radiation tolerance narrowed the options in this rapidly developing field for the ATLAS and CMS upgrades to low gain avalanche detectors and silicon photomultipliers. In a variety of applications where occupancies and doses are lower, devices with pixel elements of order 1 cm2, nevertheless achieving 30 ps, would be attractive. In this paper, deep diffused Avalanche Photo Diodes (APDs) are examined as candidate timing detectors for HL-LHC applications. Devices with an active area of 8 × 8 mm are characterised using a pulsed infrared laser and, in some cases, high energy particle beams. The timing performance as well as the uniformity of response are examined. The effects of radiation damage on current, signal amplitude, noise, and timing of the APDs are evaluated using detectors with an active area of 2 × 2 mm. These detectors were irradiated with neutrons up to a 1-MeV neutrons fluence cm−2. Their timing performance was characterised using a pulsed infrared laser. While a time resolution of ps was obtained in a beam test using an 8 × 8 mm sensor, the present study only demonstrates that gain loss can be compensated by increased detector bias up to fluences of cm−2. So it possibly falls short of the cm−2 requirement for the CMS barrel over the lifetime of the HL-LHC.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11582/331406
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact