The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of 180 ps, a time resolution of about 30 ps is needed. The timing detectors will experience a 1-MeV neutron equivalent fluence of about and cm−2 for the barrel and end-cap regions, respectively. In this contribution, deep diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate timing detectors for HL-LHC applications. To improve the detector’s timing performance, the APDs are used to directly detect the traversing particles, without a radiator medium where light is produced. Devices with an active area of 8 × 8 mm were characterized in beam tests. The timing performance and signal properties were measured as a function of position on the detector using a beam telescope and a microchannel plate photomultiplier (MCP-PMT). Devices with an active area of 2 × 2 mm were used to determine the effects of radiation damage and characterized using a ps pulsed laser. These detectors were irradiated with neutrons up to cm−2.
Deep diffused Avalanche photodiodes for charged particles timing
M. Centis Vignali;
2020-01-01
Abstract
The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of 180 ps, a time resolution of about 30 ps is needed. The timing detectors will experience a 1-MeV neutron equivalent fluence of about and cm−2 for the barrel and end-cap regions, respectively. In this contribution, deep diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate timing detectors for HL-LHC applications. To improve the detector’s timing performance, the APDs are used to directly detect the traversing particles, without a radiator medium where light is produced. Devices with an active area of 8 × 8 mm were characterized in beam tests. The timing performance and signal properties were measured as a function of position on the detector using a beam telescope and a microchannel plate photomultiplier (MCP-PMT). Devices with an active area of 2 × 2 mm were used to determine the effects of radiation damage and characterized using a ps pulsed laser. These detectors were irradiated with neutrons up to cm−2.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.