A ferromagnetic axion haloscope searches for dark matter in the form of axions by exploiting their interaction with electronic spins. It is composed of an axion-to-electromagnetic field transducer coupled to a sensitive rf detector. The former is a photon-magnon hybrid system, and the latter is based on a quantum-limited Josephson parametric amplifier. The hybrid system consists of ten 2.1 mm diameter yttrium iron garnet spheres coupled to a single microwave cavity mode by means of a static magnetic field. Our setup is the most sensitive rf spin magnetometer ever realized. The minimum detectable field is 5.5×10^{-19}  T with 9 h integration time, corresponding to a limit on the axion-electron coupling constant g_{aee}≤1.7×10^{-11} at 95% C.L. The scientific run of our haloscope resulted in the best limit on dark matter axions to electron coupling constant in a frequency span of about 120 MHz, corresponding to the axion-mass range 42.4-43.1  μeV. This is also the first apparatus to perform a wide axion-mass scanning by only changing the static magnetic field.

Axion Search with a Quantum-Limited Ferromagnetic Haloscope

Falferi, P.;
2020-01-01

Abstract

A ferromagnetic axion haloscope searches for dark matter in the form of axions by exploiting their interaction with electronic spins. It is composed of an axion-to-electromagnetic field transducer coupled to a sensitive rf detector. The former is a photon-magnon hybrid system, and the latter is based on a quantum-limited Josephson parametric amplifier. The hybrid system consists of ten 2.1 mm diameter yttrium iron garnet spheres coupled to a single microwave cavity mode by means of a static magnetic field. Our setup is the most sensitive rf spin magnetometer ever realized. The minimum detectable field is 5.5×10^{-19}  T with 9 h integration time, corresponding to a limit on the axion-electron coupling constant g_{aee}≤1.7×10^{-11} at 95% C.L. The scientific run of our haloscope resulted in the best limit on dark matter axions to electron coupling constant in a frequency span of about 120 MHz, corresponding to the axion-mass range 42.4-43.1  μeV. This is also the first apparatus to perform a wide axion-mass scanning by only changing the static magnetic field.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11582/325366
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
social impact