The high light output and fast decay time of LaBr3:Ce scintillation detectors leads to excellent timingperformance. To realize the potential of timing resolution with LaBr3:Ce we have investigated the performance with SiPMs, which enable 1-to-1 coupling to individual crystals, and which have been optimized for the near-ultraviolet (NUV) scintillation light emission of LaBr3:Ce. Coincidence timing resolution (CTR) of 100 ps was measured for a 4x4x5mm^3 LaBr3:30%Ce crystal directly coupled to a large-area 4x4mm^2 NUV-SiPM. Results show very little dependence on temperature, in the range of -20C to 20C, and bias voltage, from 2 V to 5 V over breakdown. Optimal performance was achieved at an over-voltage (OV) range of 3 V – 5 V, at which high gain and high photon detection efficiency are achieved. Though saturation was evident at 511 keV, an energy resolution of 6.8% was measured after correcting for non-linearity. We also measured a CTR of 110 ps for a 4x4x5mm^3 LaBr3:5%Ce crystal and 245 ps for a 4x4x30mm^3 LaBr3:5%Ce crystal using the NUV-SIPM. The poorer timing measurement for the 30-mm long crystal is due mainly to a systematic shift in the time pick-off as a function of the depth-of-interaction. The excellent temperature stability, fast rise time, high gain, and low noise of the NUV-SiPM make it a practical and highly appealing photodetector for the readout of a LaBr3:Ce TOF-PET detector.

Timing and Energy Resolution of New Near-UV SiPMs Coupled to LaBr3:Ce for TOF-PET

Ferri, Alessandro;Gola, Alberto Giacomo;Tarolli, Alessandro;Piemonte, Claudio;
2014-01-01

Abstract

The high light output and fast decay time of LaBr3:Ce scintillation detectors leads to excellent timingperformance. To realize the potential of timing resolution with LaBr3:Ce we have investigated the performance with SiPMs, which enable 1-to-1 coupling to individual crystals, and which have been optimized for the near-ultraviolet (NUV) scintillation light emission of LaBr3:Ce. Coincidence timing resolution (CTR) of 100 ps was measured for a 4x4x5mm^3 LaBr3:30%Ce crystal directly coupled to a large-area 4x4mm^2 NUV-SiPM. Results show very little dependence on temperature, in the range of -20C to 20C, and bias voltage, from 2 V to 5 V over breakdown. Optimal performance was achieved at an over-voltage (OV) range of 3 V – 5 V, at which high gain and high photon detection efficiency are achieved. Though saturation was evident at 511 keV, an energy resolution of 6.8% was measured after correcting for non-linearity. We also measured a CTR of 110 ps for a 4x4x5mm^3 LaBr3:5%Ce crystal and 245 ps for a 4x4x30mm^3 LaBr3:5%Ce crystal using the NUV-SIPM. The poorer timing measurement for the 30-mm long crystal is due mainly to a systematic shift in the time pick-off as a function of the depth-of-interaction. The excellent temperature stability, fast rise time, high gain, and low noise of the NUV-SiPM make it a practical and highly appealing photodetector for the readout of a LaBr3:Ce TOF-PET detector.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11582/250675
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact