In the framework of our research work, we are developing a microfluidic system that can be used as a pre-treatment device for the sample preparation in analytical microsystems, as biosensors, for instance. Sample pre-treatment phase is usually envisaged before chemical and biological analysis. For example, if we want to perform contaminants detection in a complex matrix as milk, we must consider that the sample consists in a solution of butterfat globules and water with dissolved carbohydrates and protein complexes. If we want a bio-sensor to perform a label free detection of some target-contaminants in milk, interferents in the matrix must be removed. Proteins are an important part of these interferents, and their concentration needs to be reduced, in order to avoid fouling and consequently the inhibition of the sensor, or false positive results in the analysis. We have designed and fabricated a SPLITT flow thin fractionation device for protein separation that is now under testing with a BSA solution.

A continuous flow microelectrophoretic module for protein separation

Capuano, Andrea;Adami, Andrea;Mulloni, Viviana;Lorenzelli, Leandro
2017-01-01

Abstract

In the framework of our research work, we are developing a microfluidic system that can be used as a pre-treatment device for the sample preparation in analytical microsystems, as biosensors, for instance. Sample pre-treatment phase is usually envisaged before chemical and biological analysis. For example, if we want to perform contaminants detection in a complex matrix as milk, we must consider that the sample consists in a solution of butterfat globules and water with dissolved carbohydrates and protein complexes. If we want a bio-sensor to perform a label free detection of some target-contaminants in milk, interferents in the matrix must be removed. Proteins are an important part of these interferents, and their concentration needs to be reduced, in order to avoid fouling and consequently the inhibition of the sensor, or false positive results in the analysis. We have designed and fabricated a SPLITT flow thin fractionation device for protein separation that is now under testing with a BSA solution.
File in questo prodotto:
File Dimensione Formato  
Capuano (1).pdf

non disponibili

Descrizione: Abstract
Tipologia: Abstract
Licenza: DRM non definito
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11582/309121
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact