In this paper, we present the results of the characterization of the first high-density (HD) cell silicon photomultipliers produced at FBK. The most advanced prototype manufactured with this technology has a cell size of 15 x 15 μm² featuring a nominal fill factor of 48%. To reach this high area coverage, we developed a new border structure to confine the high electric-field region of each single-photon avalanche diode. The measured detection efficiency approaches 30% in the green part of the light spectrum and it is above 20% from 400 to 650 nm. At these efficiency values, the correlated noise is very low, giving an excess charge factor below 1.1. We coupled a 2 x 2 x 10-mm³ LYSO scintillator crystal to a 2.2 x 2.2-mm² silicon photomultiplier, obtaining very promising results for PET application: energy resolution of less than 11% full-width at half maximum (FWHM) with negligible loss of linearity and coincidence resolving time of 200-ps FWHM at 20 °C.

Characterization of the First FBK High-Density Cell Silicon Photomultiplier Technology

Piemonte, Claudio;Ferri, Alessandro;Gola, Alberto Giacomo;Pro, Tiziana;Serra, Nicola;Tarolli, Alessandro;Zorzi, Nicola
2013-01-01

Abstract

In this paper, we present the results of the characterization of the first high-density (HD) cell silicon photomultipliers produced at FBK. The most advanced prototype manufactured with this technology has a cell size of 15 x 15 μm² featuring a nominal fill factor of 48%. To reach this high area coverage, we developed a new border structure to confine the high electric-field region of each single-photon avalanche diode. The measured detection efficiency approaches 30% in the green part of the light spectrum and it is above 20% from 400 to 650 nm. At these efficiency values, the correlated noise is very low, giving an excess charge factor below 1.1. We coupled a 2 x 2 x 10-mm³ LYSO scintillator crystal to a 2.2 x 2.2-mm² silicon photomultiplier, obtaining very promising results for PET application: energy resolution of less than 11% full-width at half maximum (FWHM) with negligible loss of linearity and coincidence resolving time of 200-ps FWHM at 20 °C.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11582/177610
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact